8.2.4.5.4.3. Signal Integrity
The Signal Integrity feature offers the equivalent of an Equivalent Time oscilloscope trace of the RX PAM4 signal (later, also PAM2). The trace is done with the A/D converter in the GTM receiver also doing the data sampling / CDR function, i.e. the trace is taken after the RX equalizer.
The HW characteristics of the Versal GTM used in Freya are: Trace length = 2000 samples, sample resolution = 7 bits 2’s complement, i.e. range = -64..63.
Using the sampled eye scan feature through CLI involves two steps:
Trigger the acquisition of a trace (PL1_CTRL)
Retrieve the trace data (PL1_GET_DATA)
This command is a generic function to retrieve dynamic data related to Layer 1 / SERDES. For now, only used for signal integrity scan.
For func==0
, sampled eye scan:
result==0
: No data available.
“No data available” means that either a scan was never started, an acquisition was started and in progress, or the acquired data has become too old (e.g. older than 500 ms). The acquisition time for a trace is in the very low ms-range. If result==0
, sweep_no
and age_us
are dummy (=0), and no additional data are returned.
result==1
: Data returned. In that case, the rest of the parameters apply:
sweep_no
: per-SERDES trace acquisition counter: 1,2,3… Each trace can be returned multiple times, to different users, within its lifetime. A new trace acquisition is triggered with the PL1_CTRL command.
age_us
: The “age” of the trace data in microseconds, i.e. the time from data acquisition from hardware was completed until the time the command reply data is generated.
value
: The rest of the reply is a set of 16 bit signed 2-complement sample values. With present hardware, the range of each sample is -64..63. In XMP scripting, each sample value is represented as two bytes, msb first.
With present implementation, 2006 sample values (4012 bytes) are returned.
The first 6 sample values are so-called sampled levels: <p1> <p2> < p3> <m1> <m2> <m3>
8.2.4.5.4.3.1. Control
Corresponding low-level API class: PL1_CTRL
await port.l1.serdes[0].medium.siv.control.set(opcode=enums.Layer1Opcode.START_SCAN)
8.2.4.5.4.3.2. Data
Corresponding low-level API class: PL1_GET_DATA
resp = await port.l1.serdes[0].medium.siv.data.get()
resp.result
resp.age_us
resp.sweep_no
resp.value