PP_PHYTXEQ
code: 358
Attention
Only for the following modules:
Loki-100G-5S-2P
Thor-400G-7S-1P
Freya-800G-4S-1P
Freya-800G-4S-1P-OSFP
# set
<module-index>/<port-index> PP_PHYTXEQ [<serdes_index>] <tap0> <tap1> <tap2> <tap3> <tap4> <tap5> <mode>
# get
<module-index>/<port-index> PP_PHYTXEQ [<serdes_index>] ?
Description
Control and monitor the equalizer settings of the on-board PHY in the transmission direction (towards the transceiver cage).
Important
For different module types, the meaning of the tap values are slightly different.
Note
PP_PHYTXEQ
, PP_PHYTXEQ_LEVEL
, and PP_PHYTXEQ_COEFF
facilitate the configuration and retrieval of TX tap values, each offering a unique perspective. Modifications made with any of these parameters will result in updates to the read results across all of them.
Actions
set, get
Parameters
pre
: integer, pre for Z100 Loki, Z400 Thor, and Z800 Freya. Default = 0 (neutral)main
: integer, main for Z100 Loki, Z400 Thor, and Z800 Freya.post
: integer, post for Z100 Loki, Z400 Thor, and Z800 Freya. Default = 0 (neutral)pre2
: integer, N/A for Z100 Loki, pre2 for Z400 Thor and Z800 Freya. Default = 0 (neutral)post2_pre3
: integer, N/A for Z100 Loki, post2 for Z400 Thor, pre3 for Z800 Freya. Default = 0 (neutral)post3
: integer, N/A for Z100 Loki, post3 for Z400 Thor, N/A for Z800 Freya. Default = 0 (neutral)mode
: integer, value must be 4
Example
# set
input: 0/1 PP_PHYTXEQ [0] 2 80 3 1 4 5 4
output: <OK>
# get
input: 0/1 PP_PHYTXEQ [0] ?
output: 0/1 PP_PHYTXEQ [0] 2 80 3 1 4 5 4