PL1_PHYTXEQ
code: 442
Attention
Only for the following modules:
Freya-800G-4S-1P
Freya-800G-4S-1P-OSFP
# set
<module-index>/<port-index> PL1_PHYTXEQ [<serdes_index>] <pre3> <pre2> <pre> <main> <post>
# get
<module-index>/<port-index> PL1_PHYTXEQ [<serdes_index>] ?
Description
Control and monitor the equalizer settings of the on-board PHY in the transmission direction (towards the transceiver cage).
Note
PL1_PHYTXEQ
, PL1_PHYTXEQ_LEVEL
, and PL1_PHYTXEQ_COEFF
facilitate the configuration and retrieval of TX tap values, each offering a unique perspective. Modifications made with any of these parameters will result in updates to the read results across all of them.
Important
The following rules apply:
The sum of each tap values should <= 87.
Actions
set, get
Parameters
Example
# set
input: 0/1 PL1_PHYTXEQ [0] 1 4 5 80 3
output: <OK>
# get
input: 0/1 PL1_PHYTXEQ [0] ?
output: 0/1 PL1_PHYTXEQ [0] 1 4 5 80 3