PE_LATENCYRANGE#

code: 1646

# get
<module-index>/<port-index> PE_LATENCYRANGE [<flow_index>] ?

Description#

Retrieve minimum and maximum configurable latency per flow in nanoseconds.

Actions#

get

Parameters#

  1. min_latency: long integer, minimum and maximum configurable latency per flow in nanoseconds.

  2. max_latency: long integer, minimum and maximum configurable latency per flow in nanoseconds.

Example#

# get
input:  0/1 PE_LATENCYRANGE [0] ?
output: 0/1 PE_LATENCYRANGE [0] 123456789123 123456789123