PP_PHYTXEQ
code: 358
Attention
Use this command for the following modules:
Z100q Loki (Loki-100G-5S-2P)
Z400 Thor
Z800 Freya
# set
<module-index>/<port-index> PP_PHYTXEQ [<serdes_index>] <tap0> <tap1> <tap2> <tap3> <tap4> <tap5> <mode>
# get
<module-index>/<port-index> PP_PHYTXEQ [<serdes_index>] ?
Description
Control and monitor the equalizer settings of the on-board PHY in the Tx direction (towards the transceiver cage).
Actions
set, get
Parameters (For Z100q Loki)
Parameters (For Z400 Thor)
Parameters (For Z800 Freya)
Example
# set
input: 0/1 PP_PHYTXEQ [0] 2 80 3 1 4 5 4
output: <OK>
# get
input: 0/1 PP_PHYTXEQ [0] ?
output: 0/1 PP_PHYTXEQ [0] 2 80 3 1 4 5 4