M_SMAOUTPUT

code: 96

# set
<module-index> M_SMAOUTPUT <sma_out>

# get
<module-index> M_SMAOUTPUT ?

Description

For test modules with SMA (SubMiniature version A) connectors, selects the function of the SMA output.

Actions

set, get

Parameters

  1. sma_out: byte, the function of the SMA (SubMiniature version A) output of the module

  • DISABLED = 0

  • PASSTHROUGH = 1

  • P0SOF = 2

  • P1SOF = 3

  • REF2MHZ = 4

  • REF10MHZ = 5

  • REF125MHZ = 6

  • REF156MHZ = 7

  • P0RXCLK = 8

  • P1RXCLK = 9

  • P0RXCLK2MHZ = 10

  • P1RXCLK2MHZ = 11

  • TS_PPS = 12

Example

# set
input:  0 M_SMAOUTPUT DISABLED
output: <OK>

# get
input:  0 M_SMAOUTPUT ?
output: 0 M_SMAOUTPUT DISABLED