PL1_INJECT_ERR
code: 565
# set
<module-index>/<port-index> PL1_INJECT_ERR <type>
Description
Inject an error on the Tx port immediately when called.
Actions
set
Parameters
type: byte, the type of condition to inject.LOA = 1: Loss of Alignment (LOA) condition.HI_SER = 2: High Symbol Error Rate (Hi-SER) condition.ITB = 3: Invalid Transcode Block (ITB) condition.ERRCWD = 4: Error 64b/66b codeword condition.
Example
# set
input: 0/1 PL1_INJECT_ERR ITB
output: <OK>