PL1_INJECT_ERR

code: 565

# set
<module-index>/<port-index> PL1_INJECT_ERR <type>

Description

Inject an error on the Tx port immediately when called.

Actions

set

Parameters

  1. type: byte, the type of condition to inject.

    • LOA = 1: Loss of Alignment (LOA) condition.

    • HI_SER = 2: High Symbol Error Rate (Hi-SER) condition.

    • ITB = 3: Invalid Transcode Block (ITB) condition.

    • ERRCWD = 4: Error 64b/66b codeword condition.

Example

# set
input:  0/1 PL1_INJECT_ERR ITB
output: <OK>