PE_PTPTC_NOMINAL_INTERVAL

code: 1673

Warning

This command is under development.

# set
<module-index>/<port-index> PE_PTPTC_NOMINAL_INTERVAL <mode> <sync_interval>

# get
<module-index>/<port-index> PE_PTPTC_NOMINAL_INTERVAL ?

Description

Nominal Sync event message interval.

Actions

set, get

Parameters

  1. mode: byte,

  • CURRENT_AVG = 1, use the current average value as the nominal interval.

  • SPECIFIC = 2, use a specific value as the nominal interval.

  1. sync_interval: integer, nominal Sync event message interval. Default is 62500 µs. Will be ignored when mode == CURRENT_AVG

Example

# set
input:  0/1 PE_PTPTC_NOMINAL_INTERVAL SPECIFIC 62500
output: <OK>

# get
input:  0/1 PE_PTPTC_NOMINAL_INTERVAL ?