3.2.2. Minimum Limit Tests
Filename
xena_lt_coeff_min_limit.py
Objective
To make the test port to respond COEFF_AT_LIMIT
when decrementing a coefficient on the remote transmitter.
Configurations
Number of
<repetitions>
, default to 1- AN/LT Configuration
AN enabled/disabled.
<preset>
the remote transmitter should start.<coefficients>
of the remote transmitter.LT control action: DECREMENT
<serdes>
the serdes lane(s) to test
- Port configuration
Interface type, e.g. QSFPDD 100G CR
Serdes speed
Number of Serdes (read-only)
Procedure
If AN is enabled, test port starts AN + interactive LT. Else, start interactive LT on the port.
AN Phase
2.1. If AN result is
AN_GOOD_CHECK
, continue to LT Phase.2.2. If AN result is not
AN_GOOD_CHECK
, quit the test and report AN failure with the AN status.
LT Phase:
3.1. Request the remote transmitter to use
PAM4
orPAM with Precoding
modulation.3.2. Request the remote transmitter to use
<preset>
on each specified Serdes.3.3. Request the remote transmitter to DECREMENT coefficient on each specified Serdes.
3.4. If the response is
COEFF_AT_LIMIT
orCOEFF_NOT_SUPPORTED
, then test is OK.3.5. If the response is
EQ_AT_LIMIT
orCOEFF_EQ_AT_LIMIT
or frame lock is lost, then the test is failed.3.6. Report the response on each specified Serdes.
Stop AN and LT on the test port.
Repeat 1-4 until all
<coefficients>
are tested.Repeat 1-5 until all
<repetitions>
are tested.
Note
This test may cause the local port to lose frame lock to the remote port.
Statistics
Timestamp
Repetition #
AN status
- For each Serdes
Starting preset
- For each coefficient
Last response