3.2.2. Minimum Limit Tests

Filename

xena_lt_coeff_min_limit.py

Objective

To make the test port to respond COEFF_AT_LIMIT when decrementing a coefficient on the remote transmitter.

Configurations

  • Number of <repetitions>, default to 1

  • AN/LT Configuration
    • AN enabled/disabled.

    • <preset> the remote transmitter should start.

    • <coefficients> of the remote transmitter.

    • LT control action: DECREMENT

    • <serdes> the serdes lane(s) to test

  • Port configuration
    • Interface type, e.g. QSFPDD 100G CR

    • Serdes speed

    • Number of Serdes (read-only)

Procedure

  1. If AN is enabled, test port starts AN + interactive LT. Else, start interactive LT on the port.

  2. AN Phase

    • 2.1. If AN result is AN_GOOD_CHECK, continue to LT Phase.

    • 2.2. If AN result is not AN_GOOD_CHECK, quit the test and report AN failure with the AN status.

  3. LT Phase:

    • 3.1. Request the remote transmitter to use PAM4 or PAM with Precoding modulation.

    • 3.2. Request the remote transmitter to use <preset> on each specified Serdes.

    • 3.3. Request the remote transmitter to DECREMENT coefficient on each specified Serdes.

    • 3.4. If the response is COEFF_AT_LIMIT or COEFF_NOT_SUPPORTED, then test is OK.

    • 3.5. If the response is EQ_AT_LIMIT or COEFF_EQ_AT_LIMIT or frame lock is lost, then the test is failed.

    • 3.6. Report the response on each specified Serdes.

  4. Stop AN and LT on the test port.

  5. Repeat 1-4 until all <coefficients> are tested.

  6. Repeat 1-5 until all <repetitions> are tested.

Note

This test may cause the local port to lose frame lock to the remote port.

Statistics

  • Timestamp

  • Repetition #

  • AN status

  • For each Serdes
    • Starting preset

    • For each coefficient
      • Last response